Clinical application of magnetic resonance BLADE technology in liver imaging

LIU Hao;YAO Xiu-zhong;CHEN Cai-zhong;ZHANG Shu-jie;HE Ying;ZENG Meng-su

Journal of China Clinic Medical Imaging ›› 2014, Vol. 25 ›› Issue (6) : 406-408.

Journal of China Clinic Medical Imaging ›› 2014, Vol. 25 ›› Issue (6) : 406-408.
论著

Clinical application of magnetic resonance BLADE technology in liver imaging

  • LIU Hao1, YAO Xiu-zhong1, CHEN Cai-zhong1, ZHANG Shu-jie1, HE Ying2, ZENG Meng-su1
Author information +
History +

Abstract

Objective: To investigate the clinical value of BLADE sequence in MRI of liver. Methods: Ninty volunteers were enrolled during the period of May 2012 to May 2013. All subjects were randomly divided into three groups with digital extraction method: Group A, T2WI+FS+Trigger and K space with 100% filling. Group B: T2WI+FS+Trigger+BLADE and K space with 100% filling. Group C: T2WI+FS+Trigger+BLADE and K space with 200% filling. Image artifacts and signal to noise ratio(SNR) of normal liver parenchyma were statistically analyzed among different sequences. Results: Imaging artifacts scores of normal liver reached statistically significant difference among three groups(F=11.037, P<0.001). Imaging artifacts scores of normal liver in A group was statistically higher than group B and group C(P=0.003 and P=0.001 2 respectively); SNR of normal liver reached statistically significant difference among three groups(F=11.037, P<0.001). SNR of normal liver in A group was statistically lower than group B and group C(P=0.031 and P=0.023 respectively). Conclusion: BLADE technology can reduce artifacts in MRI of liver and improve its image quality.

Key words

Liver / Magnetic resonance imaging

Cite this article

Download Citations
LIU Hao;YAO Xiu-zhong;CHEN Cai-zhong;ZHANG Shu-jie;HE Ying;ZENG Meng-su. Clinical application of magnetic resonance BLADE technology in liver imaging[J]. Journal of China Clinic Medical Imaging. 2014, 25(6): 406-408

Accesses

Citation

Detail

Sections
Recommended

/