目的:探讨16层螺旋CT仿真内窥镜检查10mm以下不同大小的猪结肠模拟息肉的敏感性以及充气压力的选择。方法:猪结肠40cm 24段。每段制作1~2mm、3~4mm、5~6mm、7~8mm、9~10mm息肉模型5枚。24段猪结肠随机分为A、B、C 3组,每组8段。3组分别注入37.5mmHg、52.5mmHg、67.5mmHg压力的气体。每段猪结肠均行3个角度扫描,即猪结肠纵轴与扫描架平面成0°、45°、90°角。结果:不同角度、压力下息肉检出的敏感性较高,没有显著性差异。仅在气压为37.5mmHg时1~2mm的息肉检出的敏感性为75.0%,其它均为100%。结肠充气的3种压力37.5mmHg与52.5mmHg和67.5mmHg之间,结肠袋深距有显著性差异,52.5mmHg与67.5mmHg之间无显著性差异。结论:16层螺旋CT对1~2mm、3~4mm、5~6mm、7~8mm、9~10mm的息肉检出有较高的敏感性。建议52.5mmHg的气压应作为CT仿真内窥镜充气的首选压力。CT扫描时应始终维持这个压力,直到扫描结束。

Abstract

Objective: To access the ability and the optimal gas pressure of 16-MDCT virtual endoscopy in detection of simulated polyps with different sizes in pig colon. Methods: Twenty-four pieces of 40cm-long colon were divided into 3 groups randomly with the gas pressure of 37.5, 52.5 and 67.5mmHg. Each piece of colon had 5 simulated polyps with the size 1~2mm, 3~4mm, 5~6mm, 7~8mm and 9~10mm. All the pieces of colon underwent CT scanning with the angle of 0°, 45° and 90° to the gantry. Results: There was no significant difference for MDCT in detection of the polyps under different pressures and with different angles. Their sensitivities were all 100% except for the 1~2mm polyps detected under 37.5mmHg with the sensitivity of 75%. The depths of the colonic haustra were different under the above pressures, but there was no difference between 52.5mmHg and 67.5mmHg. Conclusion: The sensitivity of 16-MDCT virtual endoscopy in detection of polyps with the size ranged from 1 to 10mm is high. The optimal gas pressure is 52.5mmHg and it should be kept until the scanning is finished.

关键词

结肠息肉 / 结肠镜检查 / 计算机体层摄影 / 模型 / 动物 /

Key words

colonic polyps / colonography / computed tomographic / models / animal / swine

引用本文

导出引用
马 巍;赵贵辛;王 啸;冯艳丽;林均会;朱海波. 16-MDCT仿真内窥镜检查猪结肠模拟息肉的实验研究[J]. 中国临床医学影像杂志. 2007, 18(2): 126-129
MA Wei;ZHAO Gui-xin;WANG Xiao;FENG Yan-li;LIN Jun-hui;ZHU Hai-bo. Experimental study of simulated polyps in pig colon: detection with 16-MDCT virtual endoscopy[J]. Journal of China Clinic Medical Imaging. 2007, 18(2): 126-129
中图分类号: R574.62    R814.42   

Accesses

Citation

Detail

段落导航
相关文章

/