肝脏血流灌注对MR表观扩散系数值影响的初步研究

石 喻;郭启勇;王晓明

中国临床医学影像杂志 ›› 2007, Vol. 18 ›› Issue (8) : 540-543.

PDF(874 KB)
PDF(874 KB)
中国临床医学影像杂志 ›› 2007, Vol. 18 ›› Issue (8) : 540-543.
论著

肝脏血流灌注对MR表观扩散系数值影响的初步研究

  • 石 喻,郭启勇,王晓明
作者信息 +

Influence of blood perfusion on apparent diffusion coefficient measurement in the liver

  • SHI Yu, GUO Qi-yong, WANG Xiao-ming
Author information +
文章历史 +

摘要

目的:探讨在不同的扩散敏感系数(b值)下,肝脏血流灌注量的改变对肝右后叶、右前叶的表观扩散系数(ADC)值的影响。材料与方法:应用1.5T磁共振扫描系统对26例健康志愿者进行扩散加权成像(DWI)检查,在禁食水8小时和进食标准餐后1小时(可有效增加门脉及肝血窦的灌注量)后分别采集一次,比较进食前后的肝脏右后叶、右前叶ADC值的变化有无统计学意义,b值采用0,250,500,750s/mm2。结果:当b=750s/mm2时,无论肝右后叶、右前叶,进食前后ADC值的改变均无统计学意义(t=1.419,P=0.178;t=1.943,P=0.072),当b=250s/mm2时,进食前后的肝右后叶、右前叶ADC值改变均有统计学意义(t=3.839,P=0.002;t=5.178,P<0.001),当b=500s/mm2时,在进食前后肝右后叶ADC值的改变无统计学意义(t=1.519,P=0.151),而右前叶ADC值的改变有统计学意义(t=2.449,P=0.028)。结论:选择禁食条件、测量肝右后叶并采用较大b值(b≥500s/mm2)可能成为一种避免血流灌注对肝ADC值测量影响的有效方法,为肝脏扩散成像提供稳定、优化的ADC值测量方案。

Abstract

Objective: To assess whether hepatic diffusion measurements are influenced by hepatic perfusion changes due to different b values in both posterior and anterior segments of right lobe. Materials and Methods: DWI was performed on a 1.5T MRI unit among 26 healthy volunteers after an 8h fast and 1h after a standard meal(which is regarded as an effective method to increase hepatic perfusion including portal venous flow and hepatic sinusoidal perfusion), we used a breath-hold technique for 20.5s at b-values of 750, 500 and 250 and 0s/mm2. The hepatic apparent diffusion coefficient(ADC) values were measured and compared due to different prandial states in both posterior and anterior segments of right lobe. Results: Compared the two sets of ADCs before and after meal, the ADC measurements using b=750s/mm2 in both posterior and anterior right lobe were unaffected by the perfusion changes(t=1.419, P=0.178; t=1.943, P=0.072) whereas the ADC values from b=250s/mm2 increased significantly after meal in both posterior and anterior segments of right lobe(t=3.839, P=0.002; t=5.178, P<0.001). As for b=500s/mm2, only the ADCs in the posterior right lobe was unchanged significantly after meal(t=1.519, P=0.151) when compared to the significantly changed ADCs in the anterior right lobe(t=2.449, P=0.028). Conclusion: With regard to the measurements of ADC, the effect of perfusion can be minimized at the higher b values(b≥500s/mm2) and in the posterior right lobe at the fasted state, which may offer the most consistent ADC values and optimized measuring conditions for further studies of hepatic DWI.

关键词

/ 磁共振成像

Key words

liver / magnetic resonance imaging

引用本文

导出引用
石 喻;郭启勇;王晓明. 肝脏血流灌注对MR表观扩散系数值影响的初步研究[J]. 中国临床医学影像杂志. 2007, 18(8): 540-543
SHI Yu;GUO Qi-yong;WANG Xiao-ming. Influence of blood perfusion on apparent diffusion coefficient measurement in the liver[J]. Journal of China Clinic Medical Imaging. 2007, 18(8): 540-543
中图分类号: R333.4    R445.2   

PDF(874 KB)

Accesses

Citation

Detail

段落导航
相关文章

/