急性跟腱撕裂的超声诊断

王枫钊

中国临床医学影像杂志 ›› 2008, Vol. 19 ›› Issue (4) : 276-277.

中国临床医学影像杂志 ›› 2008, Vol. 19 ›› Issue (4) : 276-277.
论著

急性跟腱撕裂的超声诊断

  • 王枫钊
作者信息 +

Acute rupture of achilles tendon diagnosed by ultrasonography

  • WANG Feng-zhao
Author information +
文章历史 +

摘要

目的:评价急性跟腱撕裂的超声诊断价值。方法:分析32例有急性踝关节损伤病史、经手术证实为跟腱完全撕裂或部分撕裂患者的超声表现,并与手术结果对照。结果:32例超声均有异常表现,诊断跟腱完全撕裂27例,部分撕裂5例。表现为跟腱腱束连续性完全中断或部分中断。手术结果完全相符。结论:超声能准确显示跟腱撕裂的部位和程度,对临床治疗具有重要的指导意义。

Abstract

Objective: To evaluate the value of ultrasonography in diagnosing achilles tendon rupture. Methods: Ultrasonographic findings in 32 patients with operatively proved acute achilles tendon rupture were analyzed. The manifestations of ultrasonography and operation were compared. Results: The achilles tendon rupture was diagnosed on ultrasonography in 32 cases. Achilles tendon complete rupture was showed in 27 cases, partial rupture in 5 cases. Ultrasonographic appearance of achilles tendon rupture displayed complete or partial discontinuation of the fibrous bundle. The operation has the same result as that of ultrasonography. Conclusion: Ultrasonography can accurately show the degree and portion of acute achilles tendon rupture, which is very helpful for treatment.

关键词

撕裂伤 / 跟腱 / 超声检查

Key words

Lacerations / Achilles tendon / Ultrasonography