双源CT灌注参数评估胃癌生物学行为的诊断试验研究

李春志;徐荣天;于晓晶;张元元;金 焱

中国临床医学影像杂志 ›› 2011, Vol. 22 ›› Issue (6) : 406-409.

中国临床医学影像杂志 ›› 2011, Vol. 22 ›› Issue (6) : 406-409.
论著

双源CT灌注参数评估胃癌生物学行为的诊断试验研究

  • 李春志1,徐荣天2,于晓晶1,张元元1,金 焱1
作者信息 +

The research of dual source CT perfusion parameter in biological behavior of gastric carcinoma

  • LI Chun-zhi1, XU Rong-tian2, YU Xiao-jing1, ZHANG Yuan-yuan1, JIN Yan1
Author information +
文章历史 +

摘要

目的:探讨双源CT灌注参数BV、BF、Patlak P对胃癌生物学行为的评估价值。方法:使用双源CT对98例胃癌病人行灌注扫描,获得BF、BV、Patlak P值并以其对胃癌的生物学行为进行评估,以确定该灌注参数的评估价值。结果:双源CT灌注参数BF对无远隔转移组的诊断灵敏度为72.13%,特异度为64.52%,阳性预测值为81.67%,阴性预测值为52.63%,正确率为70.41%。BV对无远隔转移组的诊断灵敏度为68.66%,特异度为51.61%,阳性预测值为75.41%,阴性预测值为43.24%,正确率为63.27%。BV对癌组织局限于浆膜内的诊断灵敏度为60.00%,特异度为69.57%,阳性预测值为86.54%,阴性预测值为34.78%,正确率为62.24%。Patlak P值对癌组织局限于胃壁肌层内的诊断灵敏度为61.54%,特异度为75.86%,阳性预测值为69.57%,阴性预测值为68.75%,正确率为69.09%。Patlak P对癌组织突破浆膜的诊断诊断灵敏度为14.29%,特异度为69.23%,阳性预测值为60%,阴性预测值为20%,正确率为27.27%。结论:双源CT灌注参数BF、BV、Patlak P能够对胃癌的生物学行为进行评估,但仍有一定的局限性。

Abstract

Objective: To investigate the value of dual source CT perfusion imaging parameters, including blood volume(BV), blood flow(BF), and Patlak P value in evaluating the biological behavior of gastric carcinoma. Methods: Dual source CT perfusion imaging was performed in 98 patients of gastric carcinoma. The BV, BF, Patlak P value were obtained to study the relationship between the parameters of perfusion and the biological behavior in gastric cancer, and estimate the value of parameters. Results: The BF could predict gastric carcinoma had no distant metastasis with a sensitivity of 72.13%, a specificity of 64.52%, a positive predictive value of 81.67%, a negative predictive value of 52.63%, and an accuracy of 70.41%. The BV could predict the gastric carcinoma had no distant metastasis with a sensitivity of 68.66%, a specificity of 51.61%, a positive predictive value of 75.41%, a negative predictive value of 43.24%, and an accuracy of 63.27%. The BV could predict gastric carcinoma confined within the serous membrane with a sensitivity of 60.00%, a specificity of 69.57%, a positive predictive value of 86.54%, a negative predictive value of 34.78%, and an accuracy of 62.24%. Patlak P value could predict the gastric carcinoma confined within the muscularis with a sensitivity of 61.54%, a specificity of 75.86%, a positive predictive value of 69.57%, a negative predictive value of 68.75%, and an accuracy of 69.09%. Patlak P value also could predict the gastric carcinoma had protrude beyond the serous membrane with a sensitivity of 14.29%, a specificity of 69.23%, a positive predictive value of 60%, a negative predictive value of 20%, and an accuracy of 27.27%. Conclusion: The dual source CT perfusion imaging parameters could assess the biological behavior of gastric carcinoma, but there still has limitations.

关键词

胃肿瘤 / 体层摄影术 / X线计算机

Key words

Stomach neoplasms / Tomography / X-ray computed