摘要
目的:探讨低浓度碘对比剂(270 mgI/mL)配合低管电压在冠状动脉CTA检查中的可行性。材料与方法:将90例行冠状动脉CTA检查的患者随机分为A组和B组。A组60例应用270 mgI/mL碘对比剂同时使用迭代算法重建,再将A组根据体质量指数(BMI)分为A1组(25例)及A2组(35例),A1组(BMI<24 kg/m2)管电压为80 kV,A2组(BMI≥24 kg/m2)管电压为100 kV;B组30例应用370 mgI/mL碘对比剂,120 kV管电压。两组均采用前瞻性心电门控扫描。记录扫描辐射剂量,并对图像质量进行主、客观分析。结果:平均有效辐射剂量(ED)A1组为(2.00±0.56) mSv,A2组为(2.35±0.74) mSv,B组为(3.98±1.78) mSv,A1组与B组间及A2组与B组间均有统计学差异(t值分别为-5.34和-4.95,P<0.05)。图像质量方面,A1组与B组间及A2组与B组间主观评价优秀率无统计学差异(χ2值分别为1.10和2.04,P值均>0.05);客观评价图像噪声(SD)、信噪比(SNR)、对比噪声比(CNR)亦均无统计学差异。结论:应用尽可能低浓度的碘对比剂(270 mgI/mL)配合低管电压在冠状动脉CTA检查中是可行的,超重人群(BMI≥24 kg/m2)亦可应用,同时显著的降低了辐射剂量和碘注射量。
Abstract
Objective: To explore the feasibility of using low concentration contrast medium(270 mgI/mL) with the low tube voltage in coronary artery CTA. Materials and Methods: Ninty patients with coronary CTA examination were divided into group A and group B randomly. Group A(n=60) used contrast medium of 270 mgI/mL with sinogram-affirmed iterative reconstruction(SAFIRE). Group A was further divided into group A1(n=25) and A2(n=35) according to body mass index(BMI). Group A1(BMI<24 kg/m2) 80 kV was used for scanning, group A2(BMI≥24 kg/m2) 100 kV. The concentration of contrast medium and the tube voltage of group B(n=30) were 370 mgI/mL and 120 kV. All groups were scanned in prospective ECG-trigger gated. Radiation dose was recorded and image quality was analysed subjectively and objectively. Results: The effective dose(ED) of group A1, A2 and B were (2.00±0.56) mSv, (2.35±0.74) mSv and (3.98±1.78) mSv respectively, between group A1 and B, group A2 and B there were statistically significant(t=-5.34 and -4.95, P<0.05). In image quality, there were no statistical differences between each groups in the excellent rate(χ2=1.10 and 2.04, P>0.05). The SD, SNR and CNR of images also showed no statistical differences by objectively evaluated. Conclusion: Using low concentration contrast medium(270 mgI/mL) with low tube voltage in coronary artery CTA is feasible, especially in overweight(BMI≥24 kg/m2) population. At the same time, the radiation dose and concentration of iodine injection are reduced significantly.
关键词
冠状动脉疾病 /
体层摄影术 /
X线计算机 /
冠状血管造影术
Key words
Coronary disease /
Tomography /
X-ray computed /
Coronary angiography
常 妙;李佩玲;初金刚;赵 宇;王丽洁;徐 克.
低浓度对比剂在冠状动脉CTA检查中的可行性研究[J]. 中国临床医学影像杂志. 2014, 25(3): 172-175
CHANG Miao;LI Pei-ling;CHU Jin-gang;ZHAO Yu;WANG Li-jie;XU Ke.
Feasibility of low concentration contrast medium in coronary CT angiography[J]. Journal of China Clinic Medical Imaging. 2014, 25(3): 172-175
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}