能谱CT单能量技术优化髂静脉MSCTV血管成像质量的可行性研究

朱华勇,潘璟琍,朱卫萍,丁建荣,李杨飞,季文斌,樊树峰

中国临床医学影像杂志 ›› 2015, Vol. 26 ›› Issue (12) : 886-889.

中国临床医学影像杂志 ›› 2015, Vol. 26 ›› Issue (12) : 886-889.
论著

能谱CT单能量技术优化髂静脉MSCTV血管成像质量的可行性研究

作者信息 +

The feasibility study on optimization of image quality of iliac vein MSCTV by gemstone spectral CT imaging technique

Author information +
文章历史 +

摘要

目的:探讨能谱CT单能量技术对提高间接法髂静脉MSCTV成像质量的应用价值。方法:44例患者行髂静脉能谱CT增强扫描,获得50 keV单能量、70 keV单能量和混合能量图像,并行髂静脉MPR、CPR和MIP重建。测量3组图像中髂静脉CT值、图像噪声及CNR,由2名高年资放射科医师采用双盲法对原始数据及图像质量进行独立主观评分。3组图像数据比较采用单因素方差分析,2名医师对图像质量主观评分一致性采用Kappa检验。结果:50 keV单能量图像的髂静脉CT值、图像噪声、CNR及主观评分均高于70 keV单能量和混合能量图像,3组图像的髂静脉CT值分别为(220.72±27.90) HU、(112.76±13.42) HU和(115.55±12.80) HU,图像噪声分别为29.83±5.15、15.25±2.73和18.46±3.05,CNR分别为4.55±1.74、3.63±1.60和2.68±1.22,差异均有统计学意义(F值分别为445.404、178.996和16.356,P值均<0.01)。2名医师对3组图像的主观评价结果经检验差异有统计学意义(F值=63.825,P<0.001;F值=64.938,P<0.001)。2名医师对3组图像的主观评价结果一致性较好(Kappa=0.806,P<0.001)。结论:能谱CT单能量技术能显著提高间接法髂静脉MSCTV成像质量。

Abstract

Objective: To investigate the application value of gemstone spectral CT single energy imaging technique to improve the image quality of indirect iliac vein MSCTV. Methods: Forty-four patients underwent iliac vein CT enhanced scanning by the GSI technique. 50 keV, 70 keV monochromatic images and the mixed energy images, and reconstructed images of iliac vein MPR, CPR, MIP were obtained. CT value, image noise and CNR of iliac vein were measured, and subjective scores of the original data and the image quality were evaluated by two senior radiologists at double-blinded. One-way ANOVA was used for statistical analysis. Kappa test was used for the consistency of subjective scores. Results: The CT value, image noise, CNR and subjective score of iliac vein of 50 keV monochromatic images were statistically higher than those of 70 keV images and the mixed energy images. The CT values of iliac vein were (220.72±27.90) HU, (112.76±13.42) HU and (115.55±12.80) HU, respectively. The values of image noise were (29.83±5.15), (15.25±2.73) and (18.46±3.05), respectively. The values of CNR were (4.55±1.74), (3.63±1.60) and (2.68±1.22), respectively. The differences of CT value, image noise and CNR were statistically significant among three groups(F=445.404, 178.996 and 16.356, P<0.01). The consistency of subjective scores for three groups among radiologists was good(Kappa=0.806, P<0.001). Conclusion: The gemstone spectral CT single energy imaging technique can significantly improve the image quality of indirect iliac vein MSCTV.

关键词

髂静脉;体层摄影术 / 螺旋计算机;血管造影术

Key words

Iliac vein / Tomography, spiral computed / Angiography

引用本文

导出引用
朱华勇,潘璟琍,朱卫萍,丁建荣,李杨飞,季文斌,樊树峰. 能谱CT单能量技术优化髂静脉MSCTV血管成像质量的可行性研究[J]. 中国临床医学影像杂志. 2015, 26(12): 886-889
ZHU Hua-yong, PAN Jing-li, ZHU Wei-ping, DING Jian-rong, LI Yang-fei, JI Wen-bin, FAN Shu-feng. The feasibility study on optimization of image quality of iliac vein MSCTV by gemstone spectral CT imaging technique[J]. Journal of China Clinic Medical Imaging. 2015, 26(12): 886-889
中图分类号: R322.123    R814.42    R814.43   

参考文献

[1]胡毅,于寰,张铁. 间接法下肢深静脉CT成像中对比剂用量的探讨[J]. 中国CT和MRI杂志,2014,12(1):112-113.
[2]夏巍,吴晶涛,尹肖睿,等. 低管电压法与低管电流法在降低多层螺旋CT下肢静脉成像辐射剂量中的对比研究[J]. 中华放射学杂志,2013,47(4):368-370.
[3]李天然,钱根年,郑春雨,等. 16层螺旋CT静脉血管造影的影像分析[J]. 临床放射学杂志,2005,24(5):460-461.
[4]崔志鹏,马爱红,李天文,等. 64排螺旋CT静脉造影诊断下肢静脉血栓性病变[J]. 中国医学影像学杂志,2006,14(3):175-179.
[5]潘玉峰,张浩,郭晓华,等. 肺栓塞和下肢深静脉血栓的多层CT联合成像[J]. 放射学实践,2010,25(3):309-311.
[6]张晓鹏. 探索的精神和乐趣——CT能谱成像临床应用研究中的思考[J]. 中华放射学杂志,2011,45(8):709-712.
[7]孙骏,罗先富,王守安,等. 能谱CT单能量图像对提高肝静脉成像质量的临床应用研究[J]. 中华放射学杂志,2013,47(2):132-135.
[8]Huda W, Sealzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT[J]. Radiology, 2000, 217(2): 430-435.
[9]陈盈,米玉成,曾春光,等. HDCT能谱技术提高肝脏门静脉血管成像质量的可行性研究[J]. 临床放射学杂志,2012,31(1):61-64.

基金

浙江省医药卫生科技计划A类项目(编号:2013KYA223)。

Accesses

Citation

Detail

段落导航
相关文章

/