低剂量延迟期扫描在泌尿系统疾病MSCTU中的临床应用

朱玉春;邢 伟;王建良;沈纪芳

中国临床医学影像杂志 ›› 2015, Vol. 26 ›› Issue (2) : 105-110.

中国临床医学影像杂志 ›› 2015, Vol. 26 ›› Issue (2) : 105-110.
论著

低剂量延迟期扫描在泌尿系统疾病MSCTU中的临床应用

  • 朱玉春1,邢 伟2,王建良1,沈纪芳1
作者信息 +

The clinical application of low dose delay scan in MSCTU for urologic disease

  • ZHU Yu-chun1, XING Wei2, WANG Jian-liang1, SHEN Ji-fang1
Author information +
文章历史 +

摘要

目的:探讨MSCT尿路成像(MSCTU)中延迟期低剂量扫描方案(100 kV+CARE Dose 4D)对泌尿系统疾病的诊断价值,并探讨三种不同后处理重组技术(MPR/CPR、MIP、VR)图像对泌尿系统疾病诊断的敏感性。方法:34例MSCTU患者延迟期采用低剂量扫描方案,所有患者延迟期1 mm薄层数据进行CTU图像重组,并与临床、病理诊断进行对照研究。结果:34例中全尿路MSCTU图像的定位诊断准确率为97.1%(33/34),定性诊断准确率为91.2%(31/34)。三组不同图像组合对泌尿系统疾病的定位诊断准确性均高于定性诊断的准确性。其定位、定性诊断敏感性,从高到低依次为:全尿路MSCTU图像>含延迟期CT轴位>常规CT轴位,其中全尿路MSCTU图像与常规CT轴位的诊断差异有显著统计学意义(P<0.012 5),其余组合均无统计学意义(P>0.012 5)。CT尿路造影后处理重组三种技术对泌尿系统疾病的定位、定性诊断准确率从高到低依次为MPR/CPR>MIP>VR图像,定位诊断准确率高于定性诊断准确率。其中MPR/CPR技术与MIP、VR技术对照,差异均有统计学意义(P=0.000),而MIP技术与VR技术比较,两组差异均无统计学意义(P>0.012 5)。结论:MSCTU技术延迟期采用100 kV结合CARE Dose 4D技术方案,不仅能够明显减少单期辐射剂量,而且能提高泌尿系统疾病的定位、定性诊断的准确性,值得临床推广应用。

Abstract

Objective: To discuss the diagnostic value of low dose delay scan(tube voltage 100 kV+CARE Dosed 4D) in multi-slice helical computed tomography urography(MSCTU), and discuss the diagnostic sensitivity of three different post-processing recombinant technologies(MPR/CPR, MIP, VR) in urologic disease. Methods: 34 cases of patients undertook low dose scan protocol in delay phase(100 kV+CARE Dosed 4D). The 1 mm-thick CT data in the delay phase were restructed by post-processing technology and compared with clinical and pathological diagnosis. Results: In 34 cases of patients, the accuracy of localization and qualitative diagnosis of MSCTU image was 97.1%(33/34) and 91.2%(31/34), respectively. The localization and qualitative diagnostic sensitivity in three different image combinations from high to low was as follows: MSCTU image>CT axial combined with delay image>routine CT axial, and the diagnostic accuracy of localization was higher than the qualitative diagnosis. There was statistically significant difference(P<0.012 5) between MSCTU image and routine CT axial, but not for the rest of the combinations(P>0.012 5). Meanwhile, the localization and qualitative diagnostic sensitivity in three different image post-processing technologies from high to low was as follows: MPR/CPR>MIP>VR. There were statistical significant differences(P=0.000) between MPR/CPR and MIP or VR technology, while not between MIP and VR(P>0.012 5). Conclusion: MSCTU using 100 kV with CARE Dosed 4D technology in excretory phase can not only reduce radiation dose in single phase, but also have higher diagnostic accuracy in localization and qualitative diagnosis. The low dose scan protocol is worth to be widely applied in the clinic of urologic disease.

关键词

泌尿系疾病 / 体层摄影术 / 螺旋计算机

Key words

Urologic diseases / Tomography / spiral computed

引用本文

导出引用
朱玉春;邢 伟;王建良;沈纪芳. 低剂量延迟期扫描在泌尿系统疾病MSCTU中的临床应用[J]. 中国临床医学影像杂志. 2015, 26(2): 105-110
ZHU Yu-chun;XING Wei;WANG Jian-liang;SHEN Ji-fang. The clinical application of low dose delay scan in MSCTU for urologic disease[J]. Journal of China Clinic Medical Imaging. 2015, 26(2): 105-110
中图分类号: R691    R814.42   